EZ-press One Step qRT-PCR Kit

EZ-press One Step qRT-PCR Kit

  • Type:    SYBR Green One Step qRT-PCR Kits

Catalog Number:   EZB-qRT-S / EZB-qRT

Pack Size:   100 Rxns / 500 Rxns

Price:    525 USD / 2250 USD

Promotion:  420 USD / 1800 USD(43 Customers Bought)



Introduction

The EZBioscience® EZ-press One Step qRT-PCR Kit is a one-step kit to quantify RNA using SYBR Green I. With the exception of primers and template, this kit contains in four vials all the components required to perform rapid, sensitive and reproducible qRT-PCR.

10× One Step qRT Enzyme Mix contains M-MLV (RNase H-) reverse transcriptase, RNase Inhibitor, Hot Start DNA Polymerase; 2× One Step qRT Buffer contains SYBR Green I, dNTPs and optimized buffer; 50× ROX Reference Dyes are used to rectify the error of fluorescence signals between different wells.

The M-MLV Reverse Transcriptase, which is an RNA-dependent DNA polymerase with a significantly attenuated RNase H activity, can synthesize cDNA at a temperature range of 42°C to 60°C and is inactivated during the activation step of the Hot Start DNA Polymerase.

RNase inhibitor can protect RNA templates from degradation.

This buffer has been optimized to allow both reverse transcription and PCR amplification to occur in the same reaction across a wide range of templates.

Hot Start DNA Polymerase requires an activation step at 95°C for 5 minutes, which prevents non-specific amplification during cDNA synthesis.


Components

Components

EZB-qRT-S

(100 Rxns)

EZB-qRT

(500 Rxns)

10× One Step qRT   Enzyme Mix*1

200 μl

1 ml

2× One Step qRT   Buffer*2

1   ml

5   ml

50× ROX Reference Dye 1*3

44   µl

220   µl

50× ROX Reference Dye 2*3

44   µl

220   µl

*1: Contain reverse transcriptase, RNase Inhibitor, Hot Start DNA Polymerase.

*2: Contain SYBR Green I, dNTPs and optimized buffer.

*3: Used to rectify the error of fluorescence signals between different wells.


Storage

The kit should be stored at -20°C and protected from light. Avoid repeated freeze thawing. The quality of this product can be guaranteed for 18 months under recommended storage conditions.


Notice

Please select an appropriate ROX according to the real-time PCR instrument used:

Do Not Use ROX

Bio-Rad CFX96™, CFX384™,   iCycler iQ™, iQ™5, MyiQ™, MiniOpticon™,Opticon®, Opticon 2,   Chromo4™; Roche LightCycler™ 96,   Roche LightCycler™ 480; Eppendorf Mastercycler®   ep realplex, realplex 2s; Illumina   Eco qPCR; Qiagen/Corbett   Rotor-Gene® Q, Rotor-Gene® 3000, Rotor-Gene®   6000; Thermo Scientific PikoReal   Cycler; Analytikjena qTOWER 3G; Cepheid SmartCycler®.

Use ROX1 (1×)

ABI 5700, 7000, 7300, 7700, 7900,   7900HT, 7900HT Fast; StepOne™, StepOne Plus™.

Use ROX2 (1×)

ABI 7500, 7500 Fast,   Quant-Studio 3, 5, 6, 7, 12K Flex, Dx, ViiA™7; Stratagene MX3000P™, MX3005P™,   MX4000™.


Representative Results

1624264219458890.png

Figure1. GAPDH mRNA expression level in serially diluted RNA from Lentivirus were detected. The amplification plots above indicate that the target gene could be amplified efficiently and specifically.


 